CAD - How can I ajust the cement gap on a TiBase

CAD - How can I ajust the cement gap on a TiBase

Content by: Guillaume Ferrenbach
Approved by: Cecile Peyrot
Last Update: 01/13/2022

For scanned  TiBase case, the cement gap parameters are only available if you choose custom abutment.

The workflow is :

To enter the desired values you must right click on the crown, go to "Recompute":

83bfeb8efd5e2402daf8836be33a7407.png

Go to the "Prothesis Type", select "TiBase Abutment" and click "OK" 

91d318754cf33320998c314c90a265b0.pngAfter that you have an abutment, now you right click on this abutment and go to "Recompute" :

fd5f88fdce891d86a3b377d239537e90.pngIn "Coping Parameters" you can see the virtual spacing values :

4bbec74a84c66435d2a2679b82e0c563.pngEnter the desired values and click on "OK".

Now the values have been saved.

"Recompute" again and select a "Full Crown on Implant" in the "Prothesis Type".

Now you have the crown with the proper values :

deb818e4f0f266ffa9593c03431d26de.png