​Hotfix Medit Link - DWOS / CARES Stock Element

Hotfix Medit Link - DWOS / CARES
Straumann Stock Element - Not able to scan the case

Content by: Christophe Veyrat
Approved by: Cecile Peyrot
Last update: January 13th, 2022




Software: Medit Link

Release: 2.5.5-185

Order type: Implant Order with Stock Element

Description: Since Medit Link 2.5.5-185 the customer is not able to scan a case with a stock element ( more than one stock element )

Medit Link 2.5.5-185   Previous Medit Link release

                                                                 

How to work around the bug

 1/ In DWOS/CARES, Create a fake Partial order, Click on Save & Scan

2/ In Medit, Scan the model with the antagonist

3/ Export the .stl/.ply of the models ( model and antagonist )

4/ Go back to DWOS/CARES, Create the order and click on Save

5/ Open Scan Import

6/ Import the scan file as usual

Did this answer your question? Thanks for the feedback There was a problem submitting your feedback. Please try again later.