Hotfix Medit Link - DWOS / CARES Stock Element
Hotfix Medit Link - DWOS / CARES
Straumann Stock Element - Not able to scan the case
Content by: Christophe Veyrat
Approved by: Cecile Peyrot
Last update: January 13th, 2022
Software: Medit Link
Release: 2.5.5-185
Order type: Implant Order with Stock Element
Description: Since Medit Link 2.5.5-185 the customer is not able to scan a case with a stock element ( more than one stock element )
Medit Link 2.5.5-185 | Previous Medit Link release |
How to work around the bug
1/ In DWOS/CARES, Create a fake Partial order, Click on Save & Scan
2/ In Medit, Scan the model with the antagonist
3/ Export the .stl/.ply of the models ( model and antagonist )
4/ Go back to DWOS/CARES, Create the order and click on Save
5/ Open Scan Import
6/ Import the scan file as usual